Air conditioning phenolic insulation board inspection report

by:Ventech     2020-11-03
( The article abstract] : air conditioning phenolic insulation board dimensions we need to prepare a tape can be measured, phenolic plate specifications for 1200 x600 mm, margin of error of 3 to 5 mm, the average thickness of 3 mm, weight error within three percent, diagonal error is less than 6 mm. Heavy




the article takeaway:


what air conditioning phenolic insulation board inspection reports, three high, density, flame retardant performance, these are the customers are more concerned about, is also an essential part of all related inspection report. Air conditioning phenolic insulation board in the inspection report of some test data we can copy the data, the quality of procurement to phenolic board carries on the preliminary acceptance, in addition to the flame retardant performance need special together, the rest can be some equipment to test.







air conditioning phenolic insulation board picture

routine inspection:


air conditioning phenolic insulation board dimensions we need to prepare a tape measure to measure, phenolic plate specifications for 1200 x600 mm, margin of error of 3 to 5 mm, the average thickness of 3 mm, weight error within three percent, diagonal error is less than 6 mm. Weight measurement using a handheld electronic scale electronic scale or can weigh weight, use electronic said as much as possible a few phenolic foam averaging is more conform to the requirements, with weight divided by the volume is the density. Generally positive and negative difference at about 2 kg weight phenolic compound air conditioning insulation board inspection report.







B1 air conditioning phenolic insulation board inspection report

laboratory testing:


flame retardant performance and insulation performance only by experimental data to test whether qualified, air conditioning phenolic insulation board coefficient of thermal conductivity of 0. 034w/( m。 k) , flame retardant performance for the B1 level, although air conditioning phenolic insulation board inspection reports for the B1 level, in fact it's flame retardant performance is close to A level, oxygen index reached A staggering 36, at A level far ahead in the insulation material, cement mortar composite phenolic insulation board has reached A level testing standard.







grade A phenolic insulation board inspection report


the above is to introduce the relevant contents about air conditioning phenolic insulation board inspection report, hope to help you, if you need this product, single ( Aluminum foil) Caigang phenolic plate please select city bo hui, my factory production equipment advanced, timely service, wholesale prices low, sample free of charge!